MANUAL CONTROLLER PINOUT
       
The new manual controller  communicated to the inerlock box via a 15 pin  
D-sub connector. The pinout for that connector is the following:

1   - V+ ( input)  
2   -  V- (input)
3   - Th amplifier Voltage output +
4   - Th amplifier Voltage output -
5   - El amplifier Voltage output +
6   - El amplifier Voltage output -
7   - Az amplifier Voltage output +
8   - Az amplifier Voltage output -
9   - Stop interlock - (Normally closed)
10  - Stop interlock +
11   - Override interlock - ( Normally open )
12   - Override interlock - ( Normally open )

Note that the only difference with the  schematic shown on the right is that the  STOP and OVERRIDE interlock are not conencted to the manual controller cicruit anymore.


Updated by D. Barkats , Oct 25, 2004